Step 1 - Download "otii-consumption-analysis" from Github.
Step 2 - Connect otii setup to your computer and run Otii software - open New project.
otii settings: new project
project settings
-> arc
supply: power box
main voltage: 3,30V
over current protection: 0,500A
digital voltage level: check ''same as supply''
-> current
check main current
check auto range
-> voltage
check GPI1 value
-> logs
check UART
baud rate: 115200
Step 3 - In Otii software navigate to File -> Preferences -> Server and click "Start"
Step 4 - Connect the device via "tag-connect".
Step 5 - Run the command with Command Prompt or Visual Studio Code
a) Command Prompt: Navigate to your folder with "otii-consumption-analysis" and run:
Step 6 - Log file after a successful test should look like this:
OK 0.0400186968914555 μWh
OK 0.2927783995633925 μWh
OK 0.029815154270834313 μWh
OK 0.012477693194445067 μWh
OK 140.1002367360885 μWh
OK 0.02873970756828776 μWh
OK 9.717506900152328 μWh
.
----------------------------------------------------------------------
Ran 1 test in 47.983s
OK
Step 7 - Rename the device log in Otii software "week number"-"device number".